Useful Tips About Arise Web Guide System

Among the web guide machines, Arise web guide system for the mask machine is easy to operate and install. With the system, the maximum speed of the mask machine can reach 500 pieces/minute, and the maximum speed of N95 (KN95) mask machine can reach 3000 pieces/minute.

Applications For Various Industries Of Arise Web Guide System

Printing industry

Solvent-free laminating machine, bag making machine, inspection machine, labeling machine, etc.

Battery industry

Lithium laminator, lithium slitting machine, lithium coating machine, battery stacking machine, etc.

Film industry

Film blowing machine, coating machine, film splitting machine, film casting machine, etc.

Tire industry

Steel wire fiber flattener, tyre building machine, steel cord cutting machine production line, etc.

Advantages Of Arise Web Guide System

1. Aluminum alloy body

2. High precision

3. Low noise

4. Automatic web guide control system

5. Easy to install and operate

6. Professional certificated

How To Test The Arise Web Guide System

All the machines here have been installed web guide, and we don’t turn on the machine. First press the manual mode or center button. This is manual mode. This is the center button. They have the same effect. Let the machine start. If there is a deviation, adjust the upper layer of fabric then. For example, if the deviation is to the left, it needs to be adjusted to the right. In the same way, if the deviation is to the right, you must adjust to the left. Before turning on the correction, make sure that the fabric is aligned, and open the correction device after this. After adjusting the fabric, the probe is aligned with the red dot and the upper line is aligned with the edge of the fabric. Then tighten the lower screw and we will locate it.

After setting the position, turn on the automatic key. Now it is in an automatic state. If there is an offset, it will all be aligned with the upper line, and it will all be corrected gradually.Every layer is the same, and the probe in this layer should also be aligned with the red dot. The lower screw must be loosened firstly, and then the probe can be moved and aligned with the red dot. After this step, we set it in place and twist the black screw. Then turn on the automatic button. If there is a deviation, the corrector will swing and automatically correct it too. The one in the lower layer is the same, when the adjustment is done, we don’t need to operate it. After finishing these procedures, turn on all the machines in an automatic state. Now all of them run automatically, without deviation.

For more useful tips, please visit the article page on the test and operation of the web guide system.