Stenter Output Power

 After the fabric is processed by the Stenter setting machine, the guide cloth is introduced to the operating table, the guide cloth is torn apart, the main control button of the cloth feed is clicked to red, and the needle protection entrance button is turned off to "0". Start the second half of the machine, and stop when the cloth guide head reaches the cloth outfeeding roller, connect the cloth guide with the guide belt, turn off the cooling drum tension motor to "0" and start the second half of the machine until the cloth guide is completely out of the cloth rack and stop. Turn off the main cloth output control button to red, start the machine to let the chain run idly.

The stenter setting machine hits the oven button to enter the heating system interface, set the heating temperature to 150 degrees, the circulating fan power is 50%, the exhaust fan is manually controlled and the air is drawn at 100% power, which can effectively remove the residual moisture in the oven, thereby starting To the role of maintenance oven. Turn off the heating system after running for about 30 minutes, let the circulating fan and exhaust fan continue to run until the temperature in the oven drops below 100 degrees, then turn off. Turn off the main control switch of the power supply of the power-off cabinet to "OFF", and the computer will automatically store the processing data and then turn it off to clean the whole machine.

On the stenter setting machine, click the icon of the circulating fan to enter the power setting window of the circulating fan, click the total button of the circulating fan to pop up a small window for setting the power of the circulating fan, click on the number box on the white bottom to pop up a numeric keypad, enter the required output power value Press to confirm.

For the stenter setting machine, click on the upper left or upper right corner of the exhaust fan icon to enter the exhaust fan power setting window, click the manual control button and confirm, click the number box on the white background to pop up a small numeric keyboard to enter the required value and confirm. If you click the automatic control button and confirm, the exhaust fan will automatically adjust the power of the exhaust fan.

Click the digital box showing the temperature in the oven simulation icon to enter the heating window, click the heating total to set the heating temperature, or you can set the heating temperature of each oven separately. When the heating temperature is below 90 degrees, click the small fire icon to heat, and when the heating temperature is above 90 degrees, click the big fire icon to heat and confirm.

 

Turn on the front half of the Flat Screen Printer. After the cloth guide has passed the upper needle protection entrance, turn on the needle protection entrance button to "1". The conduction band is connected. Click the main control button of the cloth discharging mechanism to green, turn on the motors of the cloth discharging part to "1" (except the cooling cylinder tension motor switch), restart the machine, introduce the cloth guide into the cloth discharging rack, and then stop. Turn on the switch of the cooling cylinder tension motor to "1".